Main Page Products Cooling & heat setting

Thermostabilized cabinets for telecommunication equipment

Thermostabilized cabinets above mentioned are intended for maintaining the reliably controlled temperature regime inside thereof in areas characterized by considerable changes in the environment temperatures; such cabinets may be used for a great variety of telecommunication equipment.


Our thermostatic cabinets are intended for the prolonged autonomous functioning in remote areas without the professional maintenance network thus practically excluding the opportunity to apply the appropriate compressor type cooling systems. Usually under such conditions the possibility to make use of ceramic heat conductors is greatly aggravated as well.

 

Typical fields of application of thermostabilized telecommunication cabinets may be generally outlined below as follows:

 

  • installation of digital subscriber servicing devices within the frameworks of rural communication networks (in process of substitution of the obsolete analog systems);

  • installation of base stations within the frameworks of mobile communication and trunking networks;

  • deployment of rebroadcasting radio relay facilities;

  • arrangement of the automobile road communication systems;

  • arrangement of the intelligent transport system (ITS).

 

It seems also that the use of thermostabilized cabinets offers an efficient solution for problem of the deployment at street of various special sensitive equipment (such as video surveillance systems, GPS pickups etc.).

 

Thermal electricity systems based on non-ceramic heat exchangers TERMIONA allow to maintain inside cabinets with the installed equipment preset temperature within the range +5º С to +30º С (given the environment temperature varying from - 40º С to +60º С).


Technical specification:

Parameter name

Value

Tolerance

Range of temperature maintained inside cabinet, oС

20º C to 30º C

+/-1,5

Environmental temperature, oС

- 40º C to +60º C

 

 

Maximum cooling performance, W

100

+/- 4

Cooling performance under environmental temperature + 60?С, W

50

+/- 2

Maximum heating capacity, W

150

 

 

Maximum thermal output provided by equipment installed inside cabinet, W

50

 

 

Internal volume, mm

270 х 220 х 440

 

 

Overall dimensions, mm

500 х 335 х 350

 

 

Weight, kgs

22